I’m an Applicator

Ashford Formula wants you to find all the information that you need. To get you started, follow the links we’ve provided here. Feel free to browse wherever you’d like, we’ll stay here to guide you.

Close

I’m a Building Owner

Ashford Formula wants you to find all the information that you need. To get you started, follow the links we’ve provided here. Feel free to browse wherever you’d like, we’ll stay here to guide you.

Close

I’m a Contractor

Ashford Formula wants you to find all the information that you need. To get you started, follow the links we’ve provided here. Feel free to browse wherever you’d like, we’ll stay here to guide you.

Close

I’m a Specifier

Ashford Formula wants you to find all the information that you need. To get you started, follow the links we’ve provided here. Feel free to browse wherever you’d like, we’ll stay here to guide you.

Close

Technical Information

Technical Data

PRODUCT DESCRIPTION

Colorless
Odorless
Non-toxic
Non-combustible
Non-flammable

Contains no Volatile Organic Compounds (VOCs).

USES

Concrete, new and old, rough or smooth surfaces
Concrete Block
Exposed Aggregate
Any Sand/Aggregate Cement Combinations

FUNCTIONS

Seals, dust proofs, hardens, and cures.
Protects against dusting, pitting, palling, efflorescence, temperature cracking in concreteInhibits freeze/thaw deterioration.
Neutralizes excess internal alkali from concrete

PACKAGING

55 Gallon Drum/208 Liters

5 Gallon Pail/19 Liters

STORAGE LIFE

Two years. Agitate drum or pail before using.

SURFACE PREPARATION

Freshly Finished Concrete: no preparation required.

Existing Concrete: sweep, scrub, or strip concrete to remove any surface contamination or film. Product must be able to penetrate the surface without hindrance.

APPLICATION

Single application only. Apply with low-pressure sprayer (power), rollers, brush, or fine/soft bristled broom.

COVERAGE RATE

Approximately 200 square feet per gallon; 5 meters per liter. Coverage depends on the the temperature and porosity of the concrete.

CLEAN UP

Soap and water.

DRYING TIME

One to three hours. The surface may be used as soon as the application is complete and the surface is again dry to the touch. Newly laid surfaces require the normal hardening period.

APPEARANCE AFTER APPLICATION

Smooth Troweled Concrete: permanent, marble-like sheen develops within 4-12 months. Burnishing the concrete surface with a propane burnisher will accelerate the sheen.

All Other Concrete Surfaces: retention of natural finish.

TEMPERATURE LIMITS

Applicable in temperatures up to 135º F/57ºC or as low as 35ºF/1.7ºC if the concrete is covered by plastic and completely protected from freezing for a period of 6 days.

THINNERS, PRIMERS AND PAINTING

No thinners or primers required.

Painting on New Concrete: allow at least 7 drying days before applying quality grade paint on existing concrete

Painting on Existing Concrete: allow 28 days for proper curing before painting new concrete.

COLORED CONCRETE

Apply to colored concrete only after the slab is fully cured. Do not get on glass or other finished surface.

LIMITATIONS

Do Not Apply the Ashford Formula to:

Lightweight block or other extremely porous masonry containing actual holes or air pockets.

Areas previously treated with curing or sealing agents, unless these coatings have completely worn off or have been removed by chemical or mechanical means.

Technical Literature

  • REACH (Registration, Evaluation, Authorization, Restriction of Chemicals) pdf
  • The Cure For Concrete pdf
  • When Can The Ashford Formula Be Applied? pdf
  • AF MSDS pdf
  • AF MSDS (Spanish) pdf
  • AF MSDS (Europe) pdf
  • AF REACH SDS (ITALY) pdf
  • AF REACH SDS (UK) pdf
  • AF Data Sheet pdf
  • AF Manu-Spec docpdf
  • AF Application pdf
  • CCP MSDS pdf
  • CCP Data Sheet pdf
  • CFP Estimating Chart pdf
  • CFP 65 Data Sheet pdf
  • CFP 65 MSDS (A) pdf
  • CFP 65 MSDS (B) pdf
  • CFP 65 Install Guidelines pdf
  • CFP 75 Data Sheet pdf
  • CFP 75 MSDS (A) pdf
  • CFP 75 MSDS (B) pdf
  • CFP 75 Install Guidelines pdf
  • CFP 85 Data Sheet pdf
  • CFP 85 MSDS (A) pdf
  • CFP 85 MSDS (B) pdf
  • CFP 85 Install Guidelines pdf
  • CFP Color Tint Pack MSDS pdf
  • Crack Repair Data Sheet pdf
  • Crack Repair MSDS (A) pdf
  • Crack Repair MSDS (B) pdf
  • Crack Repair Guidelines pdf
  • Spall Repair Data Sheet pdf
  • Spall Repair MSDS (A) pdf
  • Spall Repair MSDS (B) pdf
  • Spall Repair Guidelines pdf
  • CFP Pump Specs pdf
  • CFP Pump Operation Info pdf
  • CreteStrip Data Sheet pdf
  • CreteStrip MSDS pdf